QS Motor Group Controller
The QS motor group controller is an interface that provides seamless integration of Quantum® and QS stand-alone systems with AC blinds, shades, louvers, projection screens, or any compatible AC motor. It provides four (4) independently controllable AC raise/ lower outputs from one common AC input feed.
Features
In QS stand-alone systems, the QS motor group controller's high-voltage outputs for motor loads can be controlled and programmed similar to QS shades. The outputs can be programmed to be controlled by: • GRAFIK Eye® QS shade button columns • seeTouch® QS shade wallstations • Pico® wireless shade controls (through a QS Sensor Module) In Quantum® systems, the QS motor group controller's high-voltage outputs for motor loads are fully programmable through the Q-DesignTM Quantum® programming software. (Contact Lutron Customer Service for availability.)
Input Power
• Input voltage: 230 V~ 50/60 Hz
• 6 A maximum total input current
• At standby (no motors being driven), power is less than 1 W
• Lightning strike protection meets ANSI/IEEE standard 62.31-1980. Can withstand voltage surges of up to 6 000 V~ and current surges of up to 3 000 A
Output Capacity
• 1,5 A maximum motor load per channel (not for lighting control)
• Each zone supports only one motor; do not wire motors in parallel
• Raise and Lower outputs are mechanically interlocked to prevent simultaneously activating Raise/Lower outputs.
• Designed to withstand 100 000 open/close cycles
Regulatory Requirements
• IEC/EN 60669-2-1, EN50428
• Lutron Quality Systems registered to ISO 9001.2008
• CE
Other Power Specifications
• Standby power: - 230 V~: 660 mW
• BTU/hour when fully loaded: 5
Environment
• Ambient temperature operating range (inside mounting panel): 0 ?C to 40 ?C (32 ?F to 104 ?F)
• Calibration point maximum: 65 ?C (149 ?F)
• Surrounding air temperature: Ta ? 65 ?C
• Relative humidity: less than 90% non-condensing
• For indoor use only
Terminals
• Mains Wiring: 1,0 to 4,0 mm2 (18 to 12 AWG)
• Zone Wiring: 1,0 to 4,0 mm2 (18 to 12 AWG)
• QS Link Wiring: See Wiring: QS Link
Mounting
• Use an IP20 (minimum) rated consumer panel or breaker panel with integrated DIN rail
• Width = 9 DIN modules (161,7 mm/6,4 in)
QS Link Limits
• A QS link can have up to 100 zones (outputs) and 100 devices
• Each QS motor group controller counts as 4 zones (outputs) and 1 device on the QS link
• The QS motor group controller (QSE-CI-4M-D) unit does not supply or consume power draw units. When using accessories (such as a keypad or a QS IR Eye, an additional 24 V- power supply or an Energi Savr Node must provide power and/or power draw units. For more information on Power Draw Units, see "Power Draw Units on the QS Link"
Out of Box Functionality
Default functionality that the unit will present when first installed:
• Unprogrammed shade keypads and/or Pico® wireless controls will raise/lower all 4 outputs when connected to a QS Sensor Module (QSM)
Normal Mode Operation
• Zone button selects the desired zone; raise/lower buttons control the selected zone
• Supports Open, Close, and Unaffected presets only; all other presets are ignored
• Does not support shade groups or areas
• Does not support discrete shade levels
• Does not support scenes
Configurable Parameters
• Minimum On time (also called Jog Time): the minimum time for which the Raise/Lower relay will be turned on. Configurable from 80 ms to 3520 ms in 80 ms increments Default: 80 ms
• Interlock delay: the time both relays are de-energized while switching from Raise to Lower, or from Lower to Raise Configurable to 320 ms, 560 ms, or 960 ms Default: 320 ms
• Maximum On time (also called Travel Time or Time to Off): after this time, the relay is turned off as a precaution. Configurable from 10 seconds to 450 seconds in 10-seond increments Default: 80 seconds